Home
NEMA 4/4X & 12 - Water/Corrosion Resistant & Dust Tight Pushbutton Fixtures
Coastal 316 - Extreme Corrosion Protection Fixtures
Classic/Antique - Cast Bronze, Yellow Brass & Aluminum - Fixtures & Dial Indicators
NEW! PhotoFixture - Full Color Faceplate Fixtures
NEMA 1 - Vandal Proof Fixtures
NEMA 7/9 & 4X C1&2,D1&2 Explosion Proof Fixtures
Custom Lantern & ADA Fixtures
Elevator Control Systems
Limit Switches
Gate Switches
Floor Switches
Machine/Slack Cable Switches
Door Interlocks
Retiring Cams
Door Restrictors
Selector Systems
Car Switches
Movie & Television Props
Need a CJA Master Paper Catalog Sent To You? Click Here!
Consultants/Architects Link
Your Shopping Cart
On-Line Catalog
Download Fixture/Controller Quotation Forms, print, fill out and fax them to 708-867-5467.
Industry Links
NEW Products!
About CJA - Terms & Conditions
Where Are We?
Privacy Statement
E-mail Us |
|
Elevator Equipment
The following is an overview of hazardous location classifications as they apply to elevator equipment. This is intended to give elevator sales, technical and field personnel a better understanding of the hazardous location designations and the equipment available to meet these requirements. The actual processes employed to define and assign hazardous location designations are complex and beyond the scope of this summary. For complete detail and installation instructions see Article 500 of the National Electrical Code.
General
Hazardous location elevator equipment is necessary in any area where the possibility of fire or explosion exists, or may exist because of flammable gases or vapors, flammable liquids, combustible dust, or ignitable fibers. These types of dangers are officially classified by location (Class, Division, and Group) depending on the properties of the flammable vapors, liquids or gases, combustible dusts or fibers that may be present and/or the likelihood that a flammable or combustible concentration or quantity is present.
From an elevator contractor perspective it is safe to say that if there is any likelihood that a fire or explosion could conceivably happen, hazardous location equipment should be installed, even if not specified by the customer.
Class I Area Classification
Areas in which flammable gases or vapors are or may be present in the air in quantities sufficient to produce explosive or ignitable mixtures are Class I.
Group A, B, C & D - Defines the type of combustible gases in the Class I location atmosphere.
Class I Area Groups:
Division 1 and 2
A (acetylene)
B (hydrogen)
C (ethylene)
D (propane)
Class II Area Classification
Areas where combustible metal, carbonaceous dust, or other combustible dust such as flour, grain, wood, etc., are or may be present in the air in quantities sufficient to produce explosive or ignitable mixtures are Class II.
Group E, F, & G - Defines the type of combustible dust in the Class II location atmosphere.
Class II Area Groups
Division 1 & 2
E (metals - Div. 1 only)
F (coal)
G (grain)
Class III Area Classification Areas that are hazardous because of the presence of easily ignitable fibers or flyings, but are not likely to be in suspension in the air in quantities sufficient to produce ignitable mixtures are Class III.
Class III Groups
Division 1 & 2
None.
Division 1 Area Classification
A Division 1 location is one in which the ignitable or combustible gases, vapors or dust can exist under normal operating conditions.
Division 2 Area Classification
A Division 2 location is one in which the ignitable or combustible gases, vapors or dust are stored, handled, processed or used, but normally confined within closed containers or systems, or dispersed by positive mechanical ventilation. In this division the hazard is created by accidental rupture of containers or systems, or equipment failure.
NEMA Classifications
Hazardous location enclosures are rated based on the Class and Group to which they will be installed. These are:
NEMA 7 - Enclosures for use in locations classified as Class I, Groups A, B, C, or D. (Combustible gases)
NEMA 9 - Enclosures for use in locations classified as Class II, Groups E, F, or G. (Combustible dust).
NEMA 4X - Enclosures for use in Class 1, Division 2 locations if used in conjunction with hermetically sealed contacts. Water/Corrosion Resistant Enclosures are constructed to provide a degree of protection against falling dirt, rain, sleet, snow, windblown dust, splashing water and corrosion.
Summary & Recommendations
To summarize these hazardous location classifications for elevator applications: (1) the Class and Group designation specifies if the exposure is gaseous or combustible dust and (2) the Division specifies if the hazard is always present or exists only when a problem occurs.
Because the Class I or II, Division 1 category indicates that the hazard exists under normal conditions it is our recommendation that elevator components used have a NEMA 7 or 9 rated enclosure. This is the most stringent application.
In Class I or II, Division 2 areas exceptions to the enclosure rating are allowed. For elevator applications in Division 2, general purpose enclosures are permissible if used in conjunction with hermetically sealed contacts. For maximum protection the general purpose enclosure should be NEMA 4X rated.
|
The Complete Elevator System
When determining what requires explosion proof protection make sure all the parts of the elevator are covered.
Whether its a passenger or freight, there are many areas of the elevator that require explosion proof protection.
CJA offers the following for your hazardous location protection needs:
Machine Room
Elevator Control Systems
For Any Speed, Type or Elevator Application
Motors: Any Horsepower/Voltage
Handset Telephones
Machine Room Lighting
Brake Limit Switches - Manual Reset
Top Of Hoistway
Final, Normal & Slow Down Switches
Access Over Travel Limit Switch
Inside Elevator
Main & Auxiliary Car Stations
For both Passenger and Freight Applications
Car Position Indicators - Digital/Multilight
Traveling Lanterns - Vandal Proof
Cab Lighting
Outside Mounted On Elevator
Car Top Inspection Station w/Worklight & Receptacle
Magna-Track Selector System
Car Bottom Worklight & Receptacle
Retiring Cam
Cab Ventilation Fan
Elevator Entrance/Hallway
Door Interlocks
Hall Stations - Loaded with Features
Multi Light Position Indicators
Hall Lanterns
Access Switch Stations
Elevator Pit/Bottom of Hoistway
Final, Normal & Slow Down Switches
Pit Switch
Pit Worklight and GFCI Receptacle
If you dont see what you need listed here please call us at 800-252-1910. If we cant help you no one can. |
|